<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-30 21-44-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 71 dBuV YLEX
Pilot RDS Phase Difference
6.1 kHz 3.1 kHz 77 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 61 kHz 12107 2,1475
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,7 dBr 3,64 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 21:44, 30.06.2025
RT
"YleX Vaihtoehto: Raine Laaksonen "
AF EON
87.6 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 61 kHz MIN: 9 kHz % above 76 kHz: 2,1475 Acquired: 2025/06/30 21.43.42 Total samples: 12107 Equivalent time: 0:10:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400